We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
CVK75S24A
Multistage ejector vacuum unit model K-75 with supply solenoid valve at 24 V AC.
SKU
CVK75S24A
Multistage ejector vacuum unit model K-75 with supply solenoid valve at 24 V AC.
Max vacuum degree [mbar] | -930 |
---|---|
Max suction air flow [Nl/min] | 4800 |
Air flow consumption [Nl/min] | 1920 |
Supply plessure [bar] | 4 ... 6 |
Working noise level [dB] | 85 |
Supply port | Maguera Ø20 int |
Vacuum port | G2 1/2" |
Materials | Al | Brass | St.Steel | NBR | HDPE | PP |
Working temperature [ºC] | -20 ... 70 |
Solenoid power cons. [W] | 10 (DC) / 8 (AC) |
Evacuation time [s] of a test volume to -100 Kpa | 0,1 |
Evacuation time [s] of a test volume to -200 Kpa | 0,2 |
Evacuation time [s] of a test volume to -300 Kpa | 0,4 |
Evacuation time [s] of a test volume to -400 Kpa | 0,9 |
Evacuation time [s] of a test volume to -500 Kpa | 1,6 |
Evacuation time [s] of a test volume to -600 Kpa | 2,5 |
Evacuation time [s] of a test volume to -700 Kpa | 4 |
Evacuation time [s] of a test volume to -800 Kpa | 7,6 |
Evacuation time [s] of a test volume to -900 Kpa | 24 |
Test volume [L] | 100 |
Type | STD |
Supply solenoid valve voltage | 24 V AC |