CVTX6SS

TRIMAX multi-stage vacuum ejector, power 06 with supply and blowing solenoid valve

SKU
CVTX6SS

TRIMAX multi-stage vacuum ejector, power 06 with supply and blowing solenoid valve

Download CAD

Download Instruction Manual CVTX (.pdf)

More Information
Max vacuum degree [mbar] -930
Max suction air flow [Nl/min] 1650
Air flow consumption [Nl/min] 420
Supply plessure [bar] 4...6
Working noise level [dB] 80
Supply port T12x10
Vacuum port G1 1/2"
Materials Al, brass, St.S, polymers
Working temperature [ºC] -20 ... 70
Solenoid power cons. [W] 2 (DC) / 3 (AC)
Evacuation time [s] of a test volume to -100 Kpa 0,3
Evacuation time [s] of a test volume to -200 Kpa 0,8
Evacuation time [s] of a test volume to -300 Kpa 1,9
Evacuation time [s] of a test volume to -400 Kpa 4,2
Evacuation time [s] of a test volume to -500 Kpa 7,1
Evacuation time [s] of a test volume to -600 Kpa 11,2
Evacuation time [s] of a test volume to -700 Kpa 18,1
Evacuation time [s] of a test volume to -800 Kpa 34
Evacuation time [s] of a test volume to -900 Kpa 94,2
Test volume [L] 100
Type STD
Supply solenoid valve voltage 24V DC
Blowing solenoid valve voltage 24V CC