EVNK1R + EVCK20

Assembly body, width 19 mm., with non-return valve + Vacuum cartridge, maximum suction flow 30 Nl/min.
SKU
EVNK1R + EVCK20
Grouped product items
Order references
EVNK1R
EVCK20

Assembly body, width 19 mm., with non-return valve + Vacuum cartridge, maximum suction flow 30 Nl/min.

Download datasheet (.pdf)

Download CAD3D file (.stp)

Download technical manual

More Information
Weight [g] 235
Max vacuum degree [mbar] -920
Max suction air flow [Nl/min] 30
Air flow consumption [Nl/min] 20
Supply plessure [bar] 4 ... 6
Working noise level [dB] 80
Supply port T6
Materials AL|Brass|ST.Steel|NBR|PP|PE
Working temperature [ºC] -20 ... 70
Vacuum port V1 G1/4"
Vacuum port V2 G1/8"
Vacuum port V3 T6
Evacuation time [s] of a test volume to -100 Kpa 5
Evacuation time [s] of a test volume to -200 Kpa 11,5
Evacuation time [s] of a test volume to -300 Kpa 19,5
Evacuation time [s] of a test volume to -400 Kpa 30
Evacuation time [s] of a test volume to -500 Kpa 45
Evacuation time [s] of a test volume to -600 Kpa 63,5
Evacuation time [s] of a test volume to -700 Kpa 88
Evacuation time [s] of a test volume to -800 Kpa 126,5
Evacuation time [s] of a test volume to -900 Kpa 241,5
Test volume [L] 25