We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Language
Multistage ejector vacuum unit SKN6 high-flow, with free expulsion and solenoid valve at 24V DC.
Multistage ejector vacuum unit SKN6 high-flow, with free expulsion and solenoid valve at 24V DC.
| Weight [g] | 3053 |
|---|---|
| Max vacuum degree [mbar] | -830 |
| Max suction air flow [Nl/min] | 2320 |
| Air flow consumption [Nl/min] | 405 |
| Supply pressure [bar] | 5 ... 6 |
| Working noise level [dB] | 80 |
| Supply port | T12x10 |
| Vacuum port | G1" |
| Materials | Al | Brass | St.Steel | PUR | HDPE | PP |
| Working temperature [ºC] | -20 ... 70 |
| Solenoid power cons. [W] | 2 (DC) / 3 (AC) |
| Evacuation time [s] of a test volume to -100 Kpa | 0,05 |
| Evacuation time [s] of a test volume to -200 Kpa | 0,1 |
| Evacuation time [s] of a test volume to -300 Kpa | 0,3 |
| Evacuation time [s] of a test volume to -400 Kpa | 0,6 |
| Evacuation time [s] of a test volume to -500 Kpa | 1,1 |
| Evacuation time [s] of a test volume to -600 Kpa | 1,8 |
| Evacuation time [s] of a test volume to -700 Kpa | 3,3 |
| Evacuation time [s] of a test volume to -800 Kpa | 6,3 |
| Test volume [L] | 25 |
| Type | AQ |
| Supply solenoid valve voltage | 24V DC |
| Quick exhaust | Free |