CVK50S24A

Multistage ejector vacuum unit model K-50 with supply solenoid valve at 24 V AC.

SKU
CVK50S24A

Multistage ejector vacuum unit model K-50 with supply solenoid valve at 24 V AC.

Download datasheet (.pdf)

Download CAD

Download Instruction Manual (.pdf)

More Information
Max vacuum degree [mbar] -930
Max suction air flow [Nl/min] 3600
Air flow consumption [Nl/min] 1440
Supply plessure [bar] 4 ... 6
Working noise level [dB] 83
Supply port T14x12
Vacuum port G2"
Materials Al | Brass | St.Steel | NBR | HDPE | PP
Working temperature [ºC] -20 ... 70
Solenoid power cons. [W] 10 (DC) / 8 (AC)
Evacuation time [s] of a test volume to -100 Kpa 0.1
Evacuation time [s] of a test volume to -200 Kpa 0,3
Evacuation time [s] of a test volume to -300 Kpa 0,5
Evacuation time [s] of a test volume to -400 Kpa 1,1
Evacuation time [s] of a test volume to -500 Kpa 2,2
Evacuation time [s] of a test volume to -600 Kpa 3,7
Evacuation time [s] of a test volume to -700 Kpa 6,2
Evacuation time [s] of a test volume to -800 Kpa 12
Evacuation time [s] of a test volume to -900 Kpa 31
Test volume [L] 100
Type STD
Supply solenoid valve voltage 24 V AC